Transformer for Extra High Voltage

Production system Format name of Hirai Primary voltage (kV) Secondary / Tertiary voltage (V) Secondary / Tertiary burden (VA) Accuracy class Insulation level Frequency (Hz) Number of phase (φ) With or without fuse Weight (kg) Notes Catalogue
Make-to-order production EPT -100E 11 110 50 1.0 class 12/28/75kV 50/60 1 no 17   JPG
Make-to-order production 11/√3 110/√3 100  
Make-to-order production EPT -100EF 11/√3 110/√3 100 1.0 class 12/28/75kV 50/60 1 yes 18   JPG
Make-to-order production EPT -75LA 12 115 75 1.0 class 12/28/95kV 50/60 1 no 23   JPG
Make-to-order production EPT -75LAF 11/√3 110/√3 100 1.0 class 12/28/75kV 50/60 1 yes 24   JPG
Make-to-order production EPT -75JA 22 115 75 1.0 class 24/50/125kV 50/60 1 no 33   JPG
Make-to-order production EPT -75JTA 39440 110 75 1.0 class 24/50/125kV 50/60 1 no 53    
6.6 15 -/22(sec.2kV)
/60kV
4.4~20 50  
14.4/√3 120/√3 12.5 ~ 200 0.3W,X,Y,1.2Z -/34(sec.2.5kV)
/95kV(BIL)
60 54 ANSI C57.13
16.8/√3 100 125kV(BIL)
110kV(BIL)
18/√3 110/√3 0.3 -/40(sec.2.5kV)
/125kV(BIL)
120/√3 0.3W,X,Y,1.2Z
Make-to-order production EPT -75JTAG 11/√3 110/√3 / 110/√3 200/200 1P / 3G 11.5/28/90kV 50/60 1 no 54 RVF=
1.1continuous
/1.73-30
minutes
 
18/√3 120/√3 / 120/3 0.3W,X,Y,1.2Z / 0.3W,X,Y,1.2Z -/60kV(IC)
/125kV(BIL)
60 IEEE Std C57.13-1993 (RVF=1.1
/ 1.9continuous)
22/√3 110/√3 / 190/3 1P / 3G 23/50/125kV 50/60 RVF=
1.1continuous
/ 1.73-30
minutes
110/√3 / 110/√3
Make-to-order production EPT -75JTAJ 19.5/√3 120/√3 200 0.3Z -/50kV(IC)
/150kV(BIL)
60 1 no 54 ANSI C57.13
(RVF=1.9/8h)
 
Make-to-order production EPT -75JTAU 11.5/√3 110/√3 100 0.2 class -/28kV(IC)
/75kV(BIL)
50/60 1 no 41   JPG
16.5/√3 120/√3   0.3W,X,Y,Z / 0.6Z -/40kV(IC)
/125kV(BIL)
60 ANSI C57.13
18 120 200 0.3W,X,Y,Z -/60kV(IC)
/125kV(BIL)
 
22 110 1.0 class -/50kV(IC)
/125kV(BIL)
 
Make-to-order production EPT -75JAGF 22/√3 110/√3 / 190/3 or 110/3V 100/100 1.0/3P class 24/50/125kV 50-60 1 yes 54   JPG
Make-to-order production EPT -20IX 11 110 200 1.0 class 12/28/75kV 50-60 1 no 27 12/36/95kV JPG
Make-to-order production EPT -100IG 11/√3 110/√3 / 190/3 or 110/3V 200/200 1.0/5G class 12/28/75kV 50-60 1 no 22.5 12/36/95kV JPG
Make-to-order production EPT -M20J 22 110 200 1.0 class 24/50/125kV 50-60 1 no 39 Capacity600VA JPG
Make-to-order production EPT -M20JG 22/√3 110/√3 200/? 1.0/3G 24/50/125kV 50-60 1 no 39    

Current Transformer for Extra High Voltage

Production system Format name of Hirai Primary current (A) Secondary / Tertiary current (A) Secondary /Tertiary burden (VA) Accuracy class Insulation level Short-time current ratings Weight (kg) Catalogue
Make-to-order production ECT-430I 50~600 5 40 1.0 class 12/28/75kV 150times/1s 14 JPG
30 5P10
Make-to-order production ECT-415I 50~600 5 40 1.0 class 12/28/75kV 150times/1s 14 JPG
15 0.5 class
Make-to-order production ECT-30IDZ 50~600 2×5 / 5 2×30/30 10P10 or 1.0 12/28/75kV 150times/1s 21 JPG
Make-to-order production ECT-30IDZ2 750~ 2×5 / 5 2×30/30 10P10 or 1.0 12/28/75kV 25kA/3s 21.6  
Make-to-order production ECT-30IDU ~750 5 50/15 C200/5G class 12/28/75kV 30kA/3s 25  
Make-to-order production ECT-40IX 5~600 5 40 1.0 class 12/28/75kV 40times/1s 15.5 JPG
Make-to-order production ECT-40IXT 10-5~300-600 5 40/40 1.0/1.0 class 12/28/75kV 40times/1s 15.5  
Make-to-order production ECT-M40J 5~300 5 40 1.0 class 24/50/150kV 40times/1s 20 JPG
Make-to-order production ECT-M40JT 10-5~300-150 5 40/40 1.0/1.0 class 24/50/150kV 40times/1s 19.5  
Make-to-order production ECT-25JD 5~600 5 50 C200 24/50/125kV 40times/1s 27 JPG
85~600 2×5 2×50 C200 or 1.0/1.2 24/50/125kV 30
800~2000 5 40 1.0 class 24/50/125kV 35

Current Transformer for Access to High Voltage Electricity (cubicle type)

Production system Format name of Hirai Primary current (A) Secondary current (A) Rated burden (VA) Circuit voltage (kV) Insulation level Frequency(Hz) Accuracy class Overcurrent intensity (times) Accuracy limit factor (n>) Number of phase (φ) Catalogue
Make-to-order production ECT-12.5KA10 20~100 5 10 6.9 6A 50/60 1.0/1PS class 12.5kA/0.125s 10 1 PDF
150~200
Make-to-order production ECT-12.5KA25 20~40 5 25 6.9 6A 50/60 1.0/1PS class 12.5kA/0.125s 10 1 PDF
50~75
100
150~200
Make-to-order production ECT-12.5KA40 20~30 5 40 6.9 6A 50/60 1.0/1PS class 12.5kA/0.125s 10 1 PDF
40~60
75
100
150~300